Ann Lab Med ; 43(3): 290-294, 2023 05 01.
Article in English | MEDLINE | ID: covidwho-2198609

ABSTRACT

While numerous studies have evaluated humoral responses to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) vaccines, data on the cellular responses to these vaccines remain sparse. We evaluated T cell responses to ChAdOx1-nCoV-19 and BNT162b2 vaccinations using an interferon gamma (IFN-γ) release assay (IGRA). ChAdOx1-nCoV-19- and BNT162b2-vaccinated participants initially showed stronger T cell responses than unvaccinated controls. The T cell response decreased over time and increased substantially after the administration of a BNT162b2 booster dose. Changes in the T cell response were less significant than those in the anti-receptor-binding domain IgG antibody titer. The study results can serve as baseline data for T cell responses after SARS-CoV-2 vaccination and suggest that the IGRA can be useful in monitoring immunogenicity.


Subject(s)
COVID-19 , ChAdOx1 nCoV-19 , Humans , BNT162 Vaccine , COVID-19 Vaccines , COVID-19/prevention & control , SARS-CoV-2 , Vaccination , Antibodies, Viral
2.
Diagnostics (Basel) ; 12(8)2022 Aug 10.
Article in English | MEDLINE | ID: covidwho-2023265

ABSTRACT

The newly developed Axis-Shield clinical chemistry heparin-binding protein (HBP) assay (Axis-Shield Diagnostics Ltd., Dundee, Scotland) can be applied to fully automated platforms. We aimed to establish a reference interval (RI) of HBP using the Axis-Shield HBP assay, and to evaluate the analytical performance of this assay. An RI was established in 212 sodium citrated plasma samples using the non-parametric method (2.5th and 97.5th percentiles). Precision, linearity, and carry-over were evaluated according to the Clinical and Laboratory Standards Institute guidelines. The RI of HBP was between 5.3 ng/mL and 171.0 ng/mL, which could be applied regardless of gender and age. Percentage coefficients of variations (%CVs) of repeatability and within-laboratory precision were 4.9% and 6.3%, respectively, for low-concentration control and 1.6% and 3.0%, respectively, for high-concentration control. The linearity was excellent (coefficient of determination (R2) = 0.99), and the carry-over rate was negligible (0.05%). This is the first study to establish an RI of HBP using the newly developed and fully automated Axis-Shield HBP assay. The Axis-Shield HBP assay showed an acceptable level of analytical performance and could be used to measure HBP concentrations effectively in routine clinical practice. Further studies are awaited to evaluate the clinical utility of HBP using this automated assay.

3.
Diagnostics (Basel) ; 12(6)2022 May 29.
Article in English | MEDLINE | ID: covidwho-1869513

ABSTRACT

BACKGROUND: Immunity against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) wanes over time after vaccination. METHODS: We compared SARS-CoV-2 antibody levels in serial samples from 350 vaccinated individuals at 3 time points (3 weeks after the first or second dose and before the third dose) with 4 assays: GenScript cPASS SARS-CoV-2 neutralization antibody detection kits (cPASS), Siemens SARS-CoV-2 IgG (sCOVG), Abbott SARS-CoV-2 IgG II Quant (CoV-2 IgG II), and an Immuno-On™ COVID-19 IgG test (Immuno-On IgG). Antibody levels by time, concordance between assays, and values from other tests corresponding to the percent inhibition results in cPASS were assessed. RESULTS: The median values at three time points were 49.31%, 90.87%, and 53.38% inhibition for cPASS, 5.39, 13.65, and 2.24 U/mL for sCOVG, 570.25, 1279.65, and 315.80 AU/mL for CoV-2 IgG II, and 223.22, 362.20, and 62.20 relative units (RU) for Immuno-On IgG. The concordance with cPASS at each time point ranged from 0.735 to 0.984, showing the highest concordance in the second sample and lowest concordance in the third in all comparative tests. The values corresponded to 30% inhibition, and the cutoffs of cPASS, were 2.02 U/mL, 258.6 AU/mL, and 74.2 RU for each test. Those for 50%, 70%, and 90% inhibition were 3.16, 5.66, and 8.26 U/mL for sCOVG, while they were 412.5, 596.9, and 1121.6 AU/mL for CoV-2 IgG II and 141.8, 248.92, and 327.14 RU for Immuno-On IgG. CONCLUSIONS: This study demonstrated the dynamic changes in antibody values at different time points using four test systems and is expected to provide useful baseline data for comparative studies and standardization efforts in the future.

4.
Front Cell Infect Microbiol ; 12: 822599, 2022.
Article in English | MEDLINE | ID: covidwho-1822354

ABSTRACT

For the clinical application of semi-quantitative anti-SARS-CoV-2 antibody tests, the analytical performance and titer correlation of the plaque reduction neutralization test (PRNT) need to be investigated. We evaluated the analytical performance and PRNT titer-correlation of one surrogate virus neutralization test (sVNT) kit and three chemiluminescent assays. We measured the total antibodies for the receptor-binding domain (RBD) of the spike protein, total antibodies for the nucleocapsid protein (NP), and IgG antibodies for the RBD. All three chemiluminescent assays showed high analytical performance for the detection of SARS-CoV-2 infection, with a sensitivity ≥ 98% and specificity ≥ 99%; those of the sVNT were slightly lower. The representativeness of the neutralizing activity of PRNT ND50 ≥ 20 was comparable among the four immunoassays (Cohen's kappa ≈ 0.80). Quantitative titer correlation for high PRNT titers of ND50 ≥ 50, 200, and 1,000 was investigated with new cut-off values; the anti-RBD IgG antibody kit showed the best performance. It also showed the best linear correlation with PRNT titer in both the acute and convalescent phases (Pearson's R 0.81 and 0.72, respectively). Due to the slowly waning titer of anti-NP antibodies, the correlation with PRNT titer at the convalescent phase was poor. In conclusion, semi-quantitative immunoassay kits targeting the RBD showed neutralizing activity that was correlated by titer; measurement of anti-NP antibodies would be useful for determining past infections.


Subject(s)
COVID-19 , Antibodies, Viral , COVID-19/diagnosis , Humans , Immunoassay , Neutralization Tests , Nucleocapsid Proteins , SARS-CoV-2
5.
Microbiol Spectr ; 9(3): e0120221, 2021 12 22.
Article in English | MEDLINE | ID: covidwho-1532981

ABSTRACT

Multiple vaccines against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) have been developed and administered to mitigate the coronavirus disease 2019 (COVID-19) pandemic. We assessed the humoral response of BNT162b2 and ChAdOx1 nCoV-19 using Siemens SARS-CoV-2 IgG (sCOVG; cutoff of ≥1.0 U/ml), Abbott SARS-CoV-2 IgG II Quant (CoV-2 IgG II; cutoff of ≥50.0 AU/ml), and GenScript cPASS SARS-CoV-2 neutralization antibody detection kits (cPASS; cutoff of ≥30% inhibition). We collected 710 serum samples (174 samples after BNT162b2 and 536 samples after ChAdOx1 nCoV-19). Venous blood was obtained 3 weeks after first and second vaccinations. In both vaccines, sCOVG, CoV-2 IgG II, and cPASS showed a high seropositive rate (>95.7%) except for cPASS after the first vaccination with ChAdOx1 nCoV-19 (68.8%). Using sCOVG and CoV-2 IgG II, the ratios of antibody value (second/first) increased 10.6- and 11.4-fold in BNT162b2 (first 14.1, second 134.8 U/ml; first 1,416.2, second 14,326.4 AU/ml) and 2.3- and 2.0-fold in ChAdOx1 nCoV-19 (first 4.0, second 9.1 U/ml; first 431.0, second 9,744.0 AU/ml). cPASS-positive results indicated a very high concordance rate with sCOVG and CoV-2 IgG II (>98%), whereas cPASS-negative results showed a relatively low concordance rate (range of 22.2% to 66.7%). To predict cPASS positivity, we suggested additional cutoffs for sCOVG and CoV-2 IgG II at 2.42 U/ml and 284 AU/ml, respectively. In conclusion, BNT162b2 and ChAdOx1 nCoV-19 evoked robust humoral responses. sCOVG and CoV-2 IgG II showed a very strong correlation with cPASS. sCOVG and CoV-2 IgG II may predict the presence of neutralizing antibodies against SARS-CoV-2. IMPORTANCE The Siemens severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) IgG (sCOVG; Siemens Healthcare Diagnostics Inc., NY, USA) and Abbott SARS-CoV-2 IgG II Quant (CoV-2 IgG II; Abbott Laboratories, Sligo, Ireland), which are automated, quantitative SARS-CoV-2-binding antibody assays, have been recently launched. This study aimed to evaluate the humoral immune response of BNT162b2 and ChAdOx1 nCoV-19 vaccines using sCOVG and CoV-2 IgG II and compare the quantitative values with the results of the GenScript surrogate virus neutralization test (cPASS; GenScript, USA Inc., NJ, USA). Our findings demonstrated that both BNT162b2 and ChAdOx1 nCoV-19 elicited a robust humoral response after the first vaccination and further increased after the second vaccination. sCOVG and CoV-2 IgG II showed a strong correlation, and the concordance rates among sCOVG, CoV-2 IgG II, and cPASS were very high in the cPASS-positive results. The additional cutoff sCOVG and CoV-2 IgG II could predict the results of cPASS.


Subject(s)
Antibodies, Neutralizing/blood , Antibodies, Viral/blood , COVID-19 Vaccines/immunology , COVID-19/immunology , Immunity, Humoral , Vaccination , Adult , BNT162 Vaccine/immunology , COVID-19/prevention & control , ChAdOx1 nCoV-19/immunology , Female , Humans , Immunoglobulin G/blood , Male , Middle Aged , SARS-CoV-2 , Serologic Tests/methods , Spike Glycoprotein, Coronavirus/immunology , Young Adult
6.
Int J Environ Res Public Health ; 18(12)2021 06 16.
Article in English | MEDLINE | ID: covidwho-1273426

ABSTRACT

Asymptomatic/mildly symptomatic coronavirus disease 2019 (COVID-19) patients produce a considerable amount of virus and transmit severe acute respiratory syndrome virus 2 (SARS-CoV-2) through close contact. Preventing in-hospital transmission of SARS-CoV-2 is challenging, since symptom-based screening protocols may miss asymptomatic/mildly symptomatic patients. In particular, dental healthcare workers (HCWs) are at high risk of exposure, as face-to-face contact and exposure to oral secretions is unavoidable. We report exposure of HCWs during dental procedures on a mild symptomatic COVID-19 patient. A 32-year-old male visited a dental clinic at a tertiary care hospital. He experienced mild cough, which started three days before the dental visit, but did not report his symptom during the entrance screening. He underwent several dental procedures and imaging for orthognathic surgery without wearing a mask. Seven HCWs were closely exposed to the patient during dental procedures that could have generated droplets and aerosols. One HCW had close contact with the patient during radiologic exams, and seven HCWs had casual contact. All HCWs wore particulate filtering respirators with 94% filter capacity and gloves, but none wore eye protection or gowns. The next day, the patient experienced dysgeusia and was diagnosed with COVID-19 with high viral load. All HCWs who had close contact with the patient were quarantined for 14 days, and polymerase chain reaction and antibody tests for SARS-CoV-2 were negative. This exposure event suggests the protective effect of particulate filtering respirators in dental clinics. The recommendations of different levels of personal protective equipment (PPE) for dental HCWs according to the procedure types should be established according to the planned procedure, the risk of COVID-19 infection of the patient, and the outbreak situation of the community.


Subject(s)
COVID-19 , Dental Clinics , Adult , Health Personnel , Humans , Infectious Disease Transmission, Patient-to-Professional/prevention & control , Male , Personal Protective Equipment , SARS-CoV-2 , Ventilators, Mechanical